Dornier Thulio Horizontal Colored

INFINITE VERSATILITY

One Laser For Your
Stone and BPH Treatments

Asset Left Curve Fix
Middle@2x
Asset Right Curve Fix(edited)
Asset Circle Curve M(edited)

Thulio® is Not a Thulium Fiber Laser

While Thulio's dusting performance rivals the TFL's6, the Thulio's 3,700 W of Maximum Peak Power provides a more powerful fragmentation7 and anatomical enucleation8, putting it in a class of it's own.

SWIPE

Peak power (max.) [W]

Power
(max.) [W]

Wavelength [nm]

Laser active
gain medium

Thulio Crystal@2x 1024x867(edited) 2

3,700

100

2013

Thulium doped YAG crystal (Yttrium-Aluminium-Garnet)

Thulium Silica

5004

604

19404

Thulium doped silica fiber4

Schematic illustrations of laser cavities.

Illustrations adopted from Traxer, O., Keller, E.X. Thulium fiber laser: the new player for kidney stone treatment? A comparison with Holmium:YAG laser. World J Urol 38, 1883–1894 (2020). https://doi.org/10.1007/s00345-019-02654-5.

Redefining Benchmarks, Surpassing Ho:YAG

Maximum Performance...

Fine and faster dusting capabilities9

55% less retropulsion5

Superior coagulation3

... in a Smaller Package

Only requires a standard power outlet

60% less floor space required10

50% reduced noise level10

Compared to Ho:YAG

REFERENCES:

1. Keller, E.X., De Coninck, V., Doizi, S. et al. (2021). Thulium fiber laser: ready to dust all urinary stone composition types? World J Urol 39, 1693–1698. https://doi.org/10.1007/s00345-020-03217-9

2. Kwok, J.L., Ventimiglia, E., De Coninck, V. et al. (2023). Pulsed thulium:YAG laser—ready to dust all urinary stone composition types? Results from a PEARLS analysis. World J Urol 41, 2823–2831. https://doi.org/10.1007/s00345-023-04549-y

3. Yilmaz, M., Esser, J., Kraft, L. et al. (2022). Experimental ex-vivo performance study comparing a novel, pulsed thulium solid-state laser, chopped thulium fibre laser, low and high-power holmium:YAG laser for endoscopic enucleation of the prostate. World J Urol 40, 601–606. https://doi.org/10.1007/s00345-021-03825-z

4. Ventimiglia, E., Robesti, D., Bevilacqua, L. et al. (2023). What to expect from the novel pulsed thulium:YAG laser? A systematic review of endourological applications. World J Urol 41, 3301–3308. https://doi.org/10.1007/s00345-023-04580-z

5. Petzold, R., Miernik, A. & Suarez-Ibarrola, R. (2021). Retropulsion force in laser lithotripsy—an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser. World J Urol 39(9), 3651–3656. https://doi.org/10.1007/s00345-021-03668-8

6. Kraft, L., Yilmaz, M., Petzold, R., et al. (2022). Dusting efficiency of a novel, pulsed Thulium: YAG laser versus a Thulium fiber laser, J Endourol., 36(2):259-265.
https://doi.org/10.1089/end.2021.0441

7. Kraft, L., Petzold, R., Suarez-Ibarrola, R. et al. (2022). In vitro fragmentation performance of a novel, pulsed Thulium solid-state laser compared to a Thulium fibre laser and standard Ho:YAG laser. Lasers Med Sci 37, 2071–2078 https://doi.org/10.1007/s10103-021-03495-8

8. von Bargen, M.F., Glienke, M., Tonyali, S. et al. (2024). Real-world experience with the new pulsed solid-state Thulium: YAG laser (Thulio) for endoscopic
enucleation of the prostate. World J Urol 42, 467. https://doi.org/10.1007/s00345-024-05141-8

9. Petzold, R., Miernik, A., & Suarez-Ibarrola, R. (2021). In Vitro Dusting Performance of a New Solid State Thulium Laser Compared to Holmium Laser Lithotripsy. J Endourol, 35(2), 221-225. https://doi.org/10.1089/end.2020.0525

10. Data on file @ Dornier MedTech

*As a result of up to 55% less retropulsion compared to Ho:YAG

Clinical Experiences

Play Video about Asset 1@2x
Play Video about Asset 2@2x
Play Video about Asset 3@2x

Latest Videos

Versatile By Design

Thulio offers a wide range of application modes, adapting to your needs and enabling smoother procedures.

1 Edited
3@2x

Dusting mode

31@2x

Fragmenting mode

Whatsapp Image 2024 09 02 At 3.49fix

Captive Fragmenting mode

Enucleation Icon

Enucleation mode

35@2x

Soft Tissue mode

36 1@2x

Flexible Short Pulse mode

38@2x

Flexible Long Pulse mode

Dusting mode

Low pulse energy, long pulse duration and high frequency provides fine and fast dusting capabilities that disintegrate particles in 125 μm and smaller.1

Dusting@2x

Fragmenting mode

High pulse energy, short pulse duration and low frequency for breaking larger or hard stones.

Fragmenting@2x

Captive® Fragmenting mode

High pulse energy, long pulse duration and low frequency for breaking larger or hard stones.
Scientifically proven to provide up to 55% reduced retropulsion*2 during fragmentation. The Dornier
Captive mode was developed to decrease the stone
movement during application – potentially reducing
correlating lithotripsy time.

Captive@2x

* compared to Ho:YAG

Enucleation mode

High pulse energy, short pulse duration and high frequency. Thulio’s RealPulse® technology enables anatomical endoscopic enucleation of the prostate.

Enucleation@2x

Soft Tissue mode

Long pulse duration and a variety of different pulse energies and frequencies. Achieves highest ranked coagulation performance**3 thanks to Tm:YAG specific water absorption.

Soft Tissue 1@2x

** compared to Ho:YAG and TFL

Flexible Short Pulse mode

Offers a full range of available settings with short pulses.

Flexible@2x

Flexible Long Pulse mode

Offers a full range of available settings with long pulses.

Flexible Long@2x

Our Most Compact 100 W Laser

Asset 9
5@2x

Ergonomic and user-friendly display

Powerful and
compact laser

  • Small footprint
    (42 x 62 cm)
  • Quiet operation
    (max. 65 dB)
  • Standard power outlet

Smart, dual footswitch

1

Ergonomic and user-friendly display

Interact with easy-to-navigate interface supported by the large rotatable touchscreen

Toggle between pre-selected settings effortlessly with dual footswitch and splitscreen function

2

Powerful and compact laser

Offer 100 W with the smallest footprint

Engineered lightweight and easy to move, with a standard wall plug

3

Smart, dual footswitch

Switch seamlessly from one pre-defined mode to another

Adjust parameter settings easily with the footswitch

RealPulse® Technology - Supercharging Thulio's Performance

Realpulse Tech@2x

RealPulse Technology is what truly distinguishes Thulio from all other lasers today, featuring:

Asset 4

Use of optimally aligned diodes deliver highly efficient energy conversion

A patented method improves laser stability and output efficiency

Use of Thulium:YAG crystal

Developed in-house with our industry-established German engineering, the Thulio delivers a pulsed laser performance so transformative, it must be experienced firsthand.

Technical Specifications

Laser type

Thulium (Tm:YAG) pulsed solid state

Wavelength

2013 nm

Output (max.)

100 W

Peak power (max.)

3.7 kW

Frequency

5-300 Hz

Application modes

Dusting, Captive Fragmenting, Standard Fragmenting, Enucleation, Soft Tissue (Coagulation), Flexible Short Pulse, Flexible Long Pulse

Weight

97 kg (laser device)
105 kg (including safe working load)

Dimensions

Including monitor:
(W) 42 x (D) 62 x (H) 139 cm

Excluding monitor:
(W) 42 x (D) 62 x (H) 112 cm

Noise emission (max.)

65 dB

Dornier Thulio® Performance Fibers

Order Number
Description
Colour Coding
Core Diameter
No. of Sterile Pieces
per Packaging
K2016360*
200 µm Single Use Thulio Laser Fiber
Blue
200 µm
3 pcs
K2016361
270 µm Slim Single Use Thulio Laser Fiber
White
272 µm
3 pcs
K2016363
400 µm Single Use Thulio Laser Fiber
Yellow
365 µm
3 pcs
K2016365
600 µm Single Use Thulio Laser Fiber
Green
550 µm
3 pcs
K2016366
1000 µm Single Use Thulio Laser Fiber
Red
940 µm
3 pcs

Dornier Thulio Performance Fibers are compatible with Dornier Thulio K2016000 only.

*Only available in EU countries (European Union)

Order Number
Description
Colour Coding
Core Diameter
No. of Sterile Pieces
per Packaging
K2016370
270 µm, Slim, 10x Reusable Thulio Laser Fiber
White
272 µm
3 pcs
K2016371
400 µm, 10x Reusable Thulio Laser Fiber
Yellow
365 µm
3 pcs
K2016372
600 µm, 10x Reusable Thulio Laser Fiber
Green
550 µm
3 pcs
K2016373
1000 µm, 10x Reusable Thulio Laser Fiber
Red
940 µm
3 pcs

Reusable Dornier Thulio Performance Fibers are authorized for 10 usage cycles (usability). Steam sterilization at 132°C (270°F). For more details, please refer to the instructions for use.

Dornier Thulio Performance Fibers are compatible with Dornier Thulio K2016000 only.

REFERENCES:

1. Petzold, R., Miernik, A., & Suarez-Ibarrola, R. (2021). In Vitro Dusting Performance of a New Solid State Thulium Laser Compared to Holmium Laser Lithotripsy. J Endourol, 35(2), 221-225. https://doi.org/10.1089/end.2020.0525

2. Petzold, R., Miernik, A., & Suarez-Ibarrola, R. (2021). Retropulsion force in laser lithotripsy-an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser. World J Urol, 39(9), 3651-3656. https://doi.org/10.1007/s00345-021-03668-8

3. Yilmaz, M., Esser, J., Kraft, L. et al. Experimental ex-vivo performance study comparing a novel, pulsed thulium solid-state laser, chopped thulium fibre laser, low and high-power holmium:YAG laser for endoscopic enucleation of the prostate. World J Urol 40, 601–606 (2022). https://doi.org/10.1007/s00345-021-03825-z

Clinical Insights

Insight into the Thulio User Experience

Across 109 tracked stone and BPH cases, physicians were highly satisfied with Thulio’s performance and capabilities.

Download
p-Tm:YAG systems rated the best for coagulation

p-Tm:YAG exhibits higher coagulation performance and better fragmentation efficiency.

Download
Advantages of p-Tm:YAG over Ho:YAG technology

p-Tm:YAG offers better fragmentation, lower retropulsion and less tissue damage.

Download

Publications

YEAR PUBLICATION REFERENCING
2024

Real-world experience with the new pulsed solid-state Thulium: YAG laser (Thulio) for endoscopic enucleation of the prostate

von Bargen, MF., Glienke, M., Tonyali, S. (2024) Real-world experience with the new pulsed solid-state Thulium: YAG laser (Thulio) for endoscopic enucleation of the prostate. World Journal of Urology. 42:467.
von Bargen, MF., Glienke, M., Tonyali, S. (2024) Real-world experience with the new pulsed solid-state Thulium: YAG laser (Thulio) for endoscopic enucleation of the prostate. World Journal of Urology. 42:467.
2023

Initial clinical experience with the pulsed solid-state thulium YAG laser from Dornier during RIRS: first 25 cases

Panthier, F., Solano, C., Chicaud, M. et al. (2023) Initial clinical experience with the pulsed solid-state thulium YAG laser from Dornier during RIRS: first 25 cases. World J Urol 41, 2119–2125. https://doi.org/10.1007/s00345-023-04501-0
Panthier, F., Solano, C., Chicaud, M. et al. (2023) Initial clinical experience with the pulsed solid-state thulium YAG laser from Dornier during RIRS: first 25 cases. World J Urol 41, 2119–2125. https://doi.org/10.1007/s00345-023-04501-0
2023

Pulsed thulium:YAG laser-ready to dust all urinary stone composition types? Results from a PEARLS analysis

Kwok, JL., Ventimiglia, E., De Coninck, V. et al. (2023) Pulsed thulium:YAG laser—ready to dust all urinary stone composition types? Results from a PEARLS analysis. World J Urol. https://doi.org/10.1007/s00345-023-04549-y
Kwok, JL., Ventimiglia, E., De Coninck, V. et al. (2023) Pulsed thulium:YAG laser—ready to dust all urinary stone composition types? Results from a PEARLS analysis. World J Urol. https://doi.org/10.1007/s00345-023-04549-y
2023

What to expect from the novel pulsed thulium:YAG laser? A systematic review of endourological applications.

Ventimiglia, E., Robesti, D., Bevilacqua, L. et al. (2023) What to expect from the novel pulsed thulium:YAG laser? A systematic review of endourological applications. World J Urol. https://doi.org/10.1007/s00345-023-04580-z
Ventimiglia, E., Robesti, D., Bevilacqua, L. et al. (2023) What to expect from the novel pulsed thulium:YAG laser? A systematic review of endourological applications. World J Urol. https://doi.org/10.1007/s00345-023-04580-z

©2024 Dornier MedTech. All rights reserved. The contents herein are subject to change without prior notice. Dornier Thulio®, Captive®, RealPulse® are registered trademarks of Dornier MedTech and its use throughout this website is protected. The information contained in this website is for information purposes only and provided "as is". The actual product may vary from the images shown. The product shown is only offered in countries where it may be legally offered. Please check the availability with your local sales representative or customer service.

Please select your preferred language

Americas

We’re here to help.

Have a question about our products and services, or general feedback for us?

We’d love to hear from you. Fill up the form below and our customer representative will get in touch shortly.

Download your clinical insights

Submit your information below to receive the download link in your mailbox

Request a Product Brochure

We can’t wait to share about our products with you! Product and brochure availability may vary between countries, but we’ll be in touch.

Download our patient brochure.

Fill out the form below to receive the download link.